Multi-channel extinction ratio tester

Multi-channel extinction ratio tester

Model No.︰8/16 channels

Brand Name︰TaiKen

Country of Origin︰China

Unit Price︰US $ 150000 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

The platform type multi-channel extinction ratio tester can independently perform polarization extinction ratio testing, optical power testing, insertion loss change testing, etc. It is equipped with a USB (RS232) interface, and the upper computer software can automatically test, record, and analyze data, making it convenient to form an automatic testing system. It is widely used in the test of optical communication equipment, optical fiber, Passive optical device and optical active devices, with wide power range, high test accuracy, high cost performance and good reliability.

 

Features

Long lifespan, low noise, low electromagnetic interference;   

Accurate measurement of power, insertion loss, etc;

Universal platform and modular plugin structure;

Facilitate the flexible formation of application target systems, facilitate maintenance, replacement, and upgrading;

Suitable for automatic detection, data recording and processing in large-scale production processes.

Applications

Measuring the extinction ratio of polarization maintaining optical fibers

Alignment of Polarization Maintaining Fiber and Laser Source

Alignment of the polarization axis of optical devices

Y-branch fiber optic gyroscope testing

Testing PM couplers and polarization beam splitters

Polarization maintaining fiber fusion monitoring

performance parameter

 

Parameter

Unit

performance index

Number of channels

8 channels/16 channels

Measure extinction ratio

dB

0~50

Measurement wavelength range

nm

1280~1630nm

measurement error

dB

≤±0.2  (PER:0~30dB, Pin≥-20dBm)

 

dB

≤±0.3  (PER:31~35dB, Pin≥-20dBm)

 

dB

≤±0.5  (PER:36~40dB, Pin≥-5dBm)

Input power range

uW

-43~+13

Effective Resolution

dB

0.1

Data update rate

Times/Channels/Second

2

communication interface

 

USBRS232

power supply

 

AC 220V

work environment

Working temperature 10~35 ℃; Working humidity: R.H. 15~80%; Storage temperature: -15~45 ℃